Version 6.5.13 build 23762 of 1st October 2025

New Features/Improvements

  • [SB-5370] Highlight matching braces in Function Generator
  • [SB-5379] Add new formula for Function Generator that changes frequency after x samples
  • [SB-5381] Do not allow removal of assigned data while AWG card is running
  • [SB-5383] Use binary prefixes (Ki, Mi, Gi, ...) throughout the program
  • [SB-5385] Show currently selected card if user tried to load a non-matching project
  • [SB-5388] Show path in error message if project or project template could not be loaded
  • [SB-5392] Number of samples in status bar should use the best matching prefix

Fixed Bugs

  • [SB-4936] Problematic reactions of the Easy-Generator with an M2p.6568-x4 regarding the activation of channels and the clock setting.
  • [SB-4943] Error when switching the channels on and off in the Easy-Generator
  • [SB-5095] Renaming sb6dat file more than once crashes SB6
  • [SB-5098] Clicking Up arrow in trigger level spinbox can create strange states
  • [SB-5189] Pulsgenerator sample view: binary factor instead decimal
  • [SB-5207] Switching off the average calculation using "delete" causes a crash.
  • [SB-5363] EasyGenerator: driver start error change start-button to stop-one
  • [SB-5366] Start EasyGenerator after stoped replay shows wrong run-state
  • [SB-5367] EasyGenerator with sinus and rectangle together: rect has wrong frequency
  • [SB-5386] "Channel input preview": custom unit might be cut off if too long
  • [SB-5387] "Set visible area" dialog shows negative samples for X axis
  • [SB-5389] Double clicking a project file with chinese characters opens SB6 but ends in "file not found" error
  • [SB-5390] XY display still uses averaging mode
  • [SB-5391] Changing result of FFT calculation from Amplitude to PSD leaves incomplete channel
  • [SB-5396] Setting crooked SR value freezes SB6
  • [SB-5400] Limit the Matlab export to 2 GB
  • [SB-5401] "Formula" calculation gets wrong value for analog signal with double as data type
  • [SB-5403] Card selection dialog returns to original size after card selection
  • [SB-5404] Card order in card selection dialog is messed up if a local card is already in use and a Netbox with more than one card has been discovered
Contact

On location for you. Choose your region.

Europe USA Asia
Contact Europe
Phone +49 (0)4102 6956-0
Fax +49 (0)4102 6956-66
E-Mail info@spec.de
Contact USA
Phone +1 (201) 562-1999
Fax +1 (201) 820-2691
E-Mail sales@spectrum-instrumentation.com
Contact Asia
Phone +61 402 130 414
E-Mail greg.tate@spectrum-instrumentation.com
Support

Request support. We are happy to help.

Support
powered by webEdition CMS