THIS PRODUCT IS END-OF-LIFE. Show more about end-life-products policy.
Recommended product:
Product:
12 bit transient recorder
Description:
The 16 models of the MI.30xx series are designed for the fast and high quality data acquisition. Every of the up to four input channels has its own A/D converter and its own programmable input amplifier. This allows to record signals with 12 bit resolution without any phase delay between them. The inputs could be selected to one of six input ranges by software and could be programmed to compensate an input offset of +/-100% of the input range. The extremely large on-board memory allows long time recording even with highest samplerates. A FIFO mode is also integrated on the board. This allows to record data continuously and to process it in the PC or to store it to hard disk.
Facts & Features:
- Up to 60 MS/s on 2 channels
- Simultaneously sampling on all channels
- 6 input ranges: +/-200 mV up to +/-10 V
- Up to 256 MSample on-board memory
- 8 MSample standard memory installed
- Window and pulsewidth trigger
- Input offset up to +/-100%
- Synchronization possible
- 33 MHz 32 bit PCI interface
- 5V / 3.3V PCI compatible
- 100% compatible to conventional PCI >= V2.1
- Sustained streaming mode up to 100 MB/s
Application examples:
- LDA/PDA
- Radar
- Production test
- Spectroscopie
- Laboratory equipment
Cascading (Optional)
The cascading option synchronizes up to 4 Spectrum boards internally. It's the simplest way to build up a multi channel system. On the internal synchronisation bus clock and trigger signals are routed between the different boards. All connected boards are then working with the same clock and trigger information. There is a phase delay between two boards of about 500 picoseconds when this synchronization option is used.
Extra I/O (Optional)
The Extra I/O module adds 24 additional digital I/O lines and 4 analog outputs on an extra connector. These additional lines are independent from the standard function and can be controlled asynchronously. There is also an internal version available with 16 digital I/Os and 4 analog outputs that can be used directly at the rear board connector.
FIFO mode
The FIFO mode is designed for continuous data transfer between measurement board and PC memory (up to 245 MB/s on a PCI-X slot, up to 125 MB/s on a PCI slot and up to 160 MB/s on a PCIe slot) or hard disk. The control of the data stream is done automatically by the driver on interrupt request. The complete installed on-board memory is used for buffer data, making the continuous streaming extremely reliable.Star-Hub (Optional)
The star-hub is an additional module allowing the phase stable synchronization of up to 16 boards in one system. Independent of the number of boards there is no phase delay between all channels. The star-hub distributes trigger and clock information between all boards. As a result all connected boards are running with the same clock and the same trigger. All trigger sources can be combined with OR/AND allowing all channels of all cards to be trigger source at the same time. The star-hub is available as 5 card and 16 card version. The 5 card version doesn't need an extra slot.Channel Trigger
The data acquisition boards offer a wide variety of trigger modes. Besides the standard signal checking for level and edge as known from oscilloscopes it's also possible to define a window trigger. Trigger conditions can be combined with logical conjunctions like OR to adopt to different application scenarios.
External Trigger
All boards can be triggered using an external TTL signal. It's possible to use positive or negative edge also in combination with a programmable pulse width. An internally recognized trigger event can - when activated by software - be routed to the trigger connector to start external instruments.
Timestamp
The timestamp option writes the time positions of the trigger events in an extra memory. The timestamps are relative to the start of recording, a defined zero time, externally synchronized to a radio clock, or a GPS receiver. With this option acquisitions of systems on different locations can be set in a precise time relation.External Clock
Using a dedicated connector a sampling clock can be fed in from an external system. It's also possible to output the internally used sampling clock to synchronize external equipment to this clock.
Reference Clock
The option to use a precise external reference clock (normally 10 MHz) is necessary to synchronize the board for high-quality measurements with external equipment (like a signal source). It's also possible to enhance the quality of the sampling clock in this way. The driver automatically generates the requested sampling clock from the fed in reference clock.Digital Inputs (Optional)
This option acquires additional synchronous digital channels phase-stable with the analog data. When the option is installed and activated additional digital inputs are stored in the unused bits of each ADC word (2 digital inputs on 14 bit A/D and 4 digital inputs on 12 bit A/D)
Programmable Input Amplifiers
The analog inputs can be adapted to real world signals using a wide variety of settings that are individual for each channel. By using software commands the input termination can be changed between 50 Ohm and 1 MOhm and one can select an input range matching the real world signal.Programmable Input Offset
Most of the Spectrum A/D cards offer a user programmable signal offset opening the Spectrum boards to a wide variety of setups. The signal offset at least covers a range of +/-100 % of the currently selected input range making unipolar measurements with the card possible. Besides this the input range offset can be programmed individually allowing a perfect match of the A/D card section to the real world signal.This standard driver is included in the card delivery and it is possible to get the newest driver version free of charge from our homepage at any time. There are no additional SDK fees for the classical text-based programming. All boards are delivered with drivers for Windows 7, Windows 8, Windows 10 and Windows 11, all 32 bit and 64 bit.
Product | Channels | Max. Samplerate | Max. Bandwidth |
---|---|---|---|
MI.3010 | 1 | 80 MS/s | 40 MHz |
MI.3011 | 2 | 40 MS/s | 20 MHz |
MI.3012 | 2 | 80 MS/s | 40 MHz |
MI.3013 | 4 | 40 MS/s | 20 MHz |
MI.3014 | 4 | 80 MS/s | 40 MHz |
MI.3015 | 2 | 160 MS/s | 40 MHz |
MI.3016 | 4 | 160 MS/s | 40 MHz |
MI.3020 | 1 | 100 MS/s | 40 MHz |
MI.3021 | 2 | 50 MS/s | 25 MHz |
MI.3022 | 2 | 100 MS/s | 40 MHz |
MI.3023 | 4 | 40 MS/s | 20 MHz |
MI.3024 | 4 | 100 MS/s | 40 MHz |
MI.3025 | 2 | 200 MS/s | 40 MHz |
MI.3026 | 4 | 200 MS/s | 40 MHz |
MI.3027 | 2 | 100 MS/s | 40 MHz |
MI.3033 | 4 | 60 MS/s | 30 MHz |
On different platforms | Bus | Max. Bus Transfer speed |
---|---|---|
M2i.3031 | PCI-X | 245 MByte/s |
M2i.3031-Exp | PCI Express x1 | 160 MByte/s |
MC.3031 | CompactPCI | 100 MByte/s |
MX.3031 | PXI | 100 MByte/s |
Documents
MI.30xx Datasheet | Data sheet of the MI.30xx family |
21.02.2022 | 366 K | |
MI.30xx Manual | Manual of MI.30xx family |
21.02.2022 | 3 M | |
Timestamp Datasheet | MI / MC Timestamp module datasheet |
21.02.2022 | 106 K | |
StarHub Datasheet | MI / MC StarHub module datasheet |
21.02.2022 | 218 K | |
Extra I/O Datasheet | MI / MC Extra I/O module datasheet |
21.02.2022 | 129 K | |
SBench 6 data sheet | Data sheet of SBench 6 |
15.01.2024 | 999 K | |
MATLAB Manual | Manual for MATLAB drivers for MI/MC/MX |
21.02.2022 | 70 K | |
LabVIEW Manual | LabVIEW Manual for MI/MC/MX.30xx |
21.02.2022 | 201 K | |
SBench 6 Manual | Manual for SBench 6 |
21.02.2022 | 7 M |
WINDOWS DRIVER + SOFTWARE
MICX_NT32 | MI/MC/MX/PCI.xxx Windows 98/NT 32 Bit Drivers |
21.02.2022 | 353 K | |
MICX_XP (32-bit) | MI/MC/MX/PCI.xxx Windows XP/Vista 32 Bit Drivers |
21.02.2022 | 381 K | |
MICX_XP (64-bit) | MI/MC/MX/PCI.xxx Windows XP/Vista 64 Bit Drivers |
21.02.2022 | 579 K | |
MICX_WIN7_8 (32-bit) | MI/MC/MX/PCI.xxx Windows 7/8 32 Bit Drivers |
4 | 21.02.2022 | 397 K |
MICX_WIN7_8 (64-bit) | MI/MC/MX/PCI.xxx Windows 7/8 64 Bit Drivers |
4 | 21.02.2022 | 604 K |
MICX_WIN10 (32-bit) | MI/MC/MX/PCI.xxx Windows 10 32 Bit Drivers |
4 | 21.02.2022 | 415 K |
MICX_WIN10 (64-bit) | MI/MC/MX/PCI.xxx Windows 10/11 64 Bit Drivers |
4 | 21.02.2022 | 627 K |
c_header | C/C++ driver header and library files |
7.01 | 22.04.2024 | 43 K |
SBench5 | SBench 5 Installer |
5.3.0 | 21.02.2022 | 5 M |
SBench6 (32-bit) | SBench 6 (32-bit) Installer / Windows 7, 8, 10 |
6.5.08 | 22.04.2024 | 36 M |
SBench6 (64-bit) | SBench 6 (64-bit) Installer / Windows 7, 8, 10, 11 |
6.5.08 | 22.04.2024 | 39 M |
MATLAB Driver | MI / MC / MX MATLAB driver + examples |
21.02.2022 | 714 K | |
LabVIEW Driver | MI / MC / MX LabVIEW Driver |
21.02.2022 | 8 M | |
Examples | MI / MC / MX Examples for C/C++, Delphi, VB, LabWindows/CVI, ... |
21.02.2022 | 700 K |
LINUX DRIVER + SOFTWARE
Linux Driver Complete | MI / MC / MX Linux 32 bit and 64 bit Drivers |
4 | 21.02.2022 | 18 M |
SBench6 | SBench 6 Linux 32 (.rpm) |
6.5.08 | 22.04.2024 | 26 M |
SBench6 | SBench 6 Linux 64 (.rpm) |
6.5.08 | 22.04.2024 | 26 M |
SBench6 | SBench 6 Linux 32 (.deb) |
6.5.08 | 22.04.2024 | 23 M |
SBench6 | SBench 6 Linux 64 (.deb) |
6.5.08 | 22.04.2024 | 22 M |
SBench6 | SBench6 Jetson (.deb) |
6.5.08 | 22.04.2024 | 11 M |
MICX Examples for Linux | MI / MC / MX Linux Examples (C/C++) |
21.02.2022 | 53 K |
Firmware
Case Studies
OCT Skin Cancer Scanner | OCT application for skin cancer diagnosis |
21.02.2022 | 351 K | |
CS Mass Spectroscopy | Case Study: Digitizer in Mass Spectroscopy |
21.02.2022 | 533 K | |
CS Digitizer at Cern | Case Study: Digitizers and AWGs at Cerns LHC Beam Dumping System |
21.02.2022 | 532 K | |
CS Spectrum Digitizers at DESY | Case Study: Spectrum Digitizers playing vital role at DESY |
21.02.2022 | 982 K | |
CS DIAL - Differential Absorption LIDAR | Case Study DIAL - Differential Absorption LIDAR |
22.02.2022 | 2 M | |
CS Smithonian Spectrometer | Case Study: Groundbreaking microwave spectrometer for research of interstellar materials |
26.07.2022 | 371 K | |
CS MPI measuring Star Diameter | Max Planck Institute uses Spectrum's digitizer cards to measure diameters of distant stars |
26.07.2022 | 320 K | |
CS Atomic Force Microscope | Case Study: Atomic Force Microscope scanning surfaces |
27.07.2022 | 293 K |
Product Notes
General Digitizer Introduction | General Introduction to Waveform Digitizers |
21.02.2022 | 587 K | |
High-Res High BW Digitizers | Advantages of High Resolution in High Bandwidth Digitizers |
21.02.2022 | 2 M | |
Digitizer Acquisition Modes | Using modular Digitizer Acquisition Modes |
21.02.2022 | 3 M | |
Digitizer Front-End | Proper Use of Digitizer Front-End Signal Conditioning |
21.02.2022 | 3 M | |
Trigger and Sync | Trigger, Clock and Synchronization Details at high-speed Digitizers |
21.02.2022 | 1 M | |
Digitizer Software Integration | Software Support for Modular Digitizers |
21.02.2022 | 724 K |
Application Notes
Ultrasonic Applications | Using Digitizers in Ultrasonic Applications |
21.02.2022 | 617 K | |
RF Measurements | RF Measurements using a modular Digitizer |
21.02.2022 | 838 K | |
Signal Processing Tools | Using Signal Processing Tools to enhance Digitizer Data |
21.02.2022 | 1 M | |
Using Probes & Sensors | Using Probes and Sensors with Modular Digitizers |
21.02.2022 | 858 K | |
Digitizers as Oscilloscope | Using a Digitizer as Oscilloscope |
21.02.2022 | 845 K | |
Solving Data Transfer Bottlenecks on Digitizers | Solving Data Transfer Bottlenecks on Digitizers |
21.02.2022 | 2 M | |
Teaming AWG with Digitizer | Teaming an Arbitrary Waveform Generator with a Modular Digitizer |
21.02.2022 | 919 K | |
Common Digitizer Setup Problems | Application Note: Common Digitizer Setup Problems to avoid |
21.02.2022 | 1 M | |
Mass Spectroscopy | Application Note Mass Spectroscopy |
21.02.2022 | 879 K | |
AN LIDAR Light Detection and Ranging | Application Note LIDAR - Light Detection and Ranging |
21.02.2022 | 528 K | |
AN Amplitude Resolution | Application Note: The Amplitude Resolution of Digitizers and how it affects Measurements |
21.02.2022 | 555 K | |
AN Radar Signal Acquisition | Application Note: Radar Signal Acquisition with Modular Digitizer |
21.02.2022 | 771 K | |
AN Dynamic Parameters and Digitizers | Application Note: Dynamic Parameters and Waveform Digitizers |
21.02.2022 | 711 K | |
AN Application examples for the ultrafast digitizers of the M5i.33xx series | Application examples for the ultrafast digitizers of the M5i.33xx series |
06.07.2023 | 1 M | |
AN M5i.33xx - New Features for Modular High-Speed Digitizer | M5i.33xx - New Features for Modular High-Speed Digitizer |
14.02.2024 | 823 K | |
AN M5i.33xx - Pulse Burst RF Measurements for NMR | AN M5i.33xx - Pulse Burst RF Measurements for NMR |
14.02.2024 | 668 K |
White Papers
Software block averaging | Using software based fast block averaging |
21.02.2022 | 649 K |