THIS PRODUCT IS OBSOLETE. Show more about end-life-products policy.
Recommended product:
Product:
16 bit high speed digitizer
Description:
The digitizerNETBOX DN2.44x series allows recording of one, two, four or eight synchronous channels with sampling rates of 130 MS/s up to 500 MS/s. These products offer outstanding A/D features in resolution, bandwidth and speed as a remote instrument. The powerful A/D amplifier section offers six different input ranges, two input paths, AC/DC coupling and noise reduction filters
Facts & Features:
- 130 MS/s on 8 channels
- 8 single-ended inputs
- Separate ADC and amplifier per channel
- Simultaneous sampling on all channels
- 6 input ranges: +/-200 mV up to +/-10 V
- Window, re-arm, OR/AND trigger
- Complete calibration circuit integrated
- High resolution digitizer with high bandwidth
- GBit Ethernet/LXI compatible instrument
- Easy connectivity with BNC/SMA connections
- SBench 6 Professional included
- Direct remote access from Workstations or Laptops
- Simple integration into the factory LAN
Product-Video:
Application examples:
- Mobile and/or shared data acquisition
- Remote controlled digitizer at experiment
- Component of LXI test system
The ABA mode combines slow continuous data recording with fast acquisition on trigger events. The ABA mode works like a slow data logger combined with a fast digitizer. The exact position of the trigger events is stored as timestamps in an extra memory.
FIFO mode
The FIFO mode is designed for continuous data transfer between the digitizerNETBOX and the host PC. The transfer speed is depending on the Ethernet connection between box and host and is in the region of 40 MB/s to 60 MB/s. The control of the data stream is done automatically by the driver on interrupt request. The complete installed on-board memory is used for buffer data, making the continuous streaming extremely reliable.Boxcar Average
The Boxcar averaging function smooths out high frequency noise to give a clear signal. It is most useful in situations where signals have been oversampled and it can be used to increase vertical resolution, lower noise and improve dynamic characteristics such as signal-to-noise ratio (SNR) and spurious free dynamic range (SFDR). It uses a mathematical signal processing function to effectively recalculate the vertical value of each acquired data point by averaging it with adjacent sample points.The digitizer allow to optionally reduce the resolution of the A/D samples from their native resolution down to 8 bit resolution, such that each sample will only occupy one byte in memory instead of the standard two bytes required. This does not only allow to store douple the amount of samples in the on-board memory, but also reduces the required bandwidth over the PCIe bus by half and also to the storage
devices, such as SSD or HDD. Using this mode much higer streaing speeds are reachable.
Digital Pulse Generator Option (Optional)
The digital pulse generator option adds three internal independent pulse generators with programmable duty cycle, output frequency, delay and number of loops. These pulse generators can be triggered by software, hardware trigger or can trigger each other allowing to form complex pulse schemes to drive external equipment or experiments. The pulse generators can be outputted on the existing multi-XIO lines or can be used to trigger the instrument internally. Time resolution of the pulse generator depends on the cards type and the selected sampling rate and can be found in the technical data section.
Channel Trigger
The data acquisition boards offer a wide variety of trigger modes. Besides the standard signal checking for level and edge as known from oscilloscopes it's also possible to define a window trigger. Trigger conditions can be combined with logical conjunctions like OR to adopt to different application scenarios.
External Trigger
All boards can be triggered using a separate external trigger signal with a two level programmable window comparator and a second separate external trigger with a single programmable level comparator. It's possible to use positive or negative edge. An internally recognized trigger event can - when activated by software - be routed to a multi purpose i/o connector to start external instruments.
Timestamp
The timestamp option writes the time positions of the trigger events in an extra memory. The timestamps are relative to the start of recording, a defined zero time, externally synchronized to a radio clock, or a GPS receiver. With this option acquisitions of systems on different locations can be set in a precise time relation.High Precision PLL
The internal sampling clock of the card is generated using a high precision PLL. This powerful device allows to select the sampling rate with a fine step size making it possible to perfectly adopt to different measurement tasks. Most other cards on the market only allow the setup of fixed sampling rates like 100 MS/s, 50 MS/s, 25 MS/s, 10 MS/s, ... without any possibility to set the sampling rate to any value in between.Reference Clock
The option to use a precise external reference clock (normally 10 MHz) is necessary to synchronize the board for high-quality measurements with external equipment (like a signal source). It's also possible to enhance the quality of the sampling clock in this way. The driver automatically generates the requested sampling clock from the fed in reference clock.Selectable AC/DC Coupling
Each analog channel contains a software selectable AC/DC coupling. When using the DC coupling all frequency parts of the signal including the DC offset are acquired. Selecting the AC coupling will only acquire frequency parts of the signal that are above a defined minimum bandwidth.On-board Calibration
The on-board calibration can be run on user request and calibrates the amplifier against a dedicated internal high precision calibration source. After this calibration data is stored permanently in an on-board EEPROM and is automatically used for further acquisitions.
Programmable Input Amplifiers
The analog inputs can be adapted to real world signals using a wide variety of settings that are individual for each channel. By using software commands the input termination can be changed between 50 Ohm and 1 MOhm and one can select an input range matching the real world signal.Selectable Input Path
For each of the analog channels the user has the choice between two analog input paths, both offering the highest flexibility when it comes to input ranges. The Buffered path has 1 MOhm termination that allows to connect standard oscilloscope probes to the card. The HF path on the other hand provides the highest bandwidth and the best signal integrity having a fixed 50 Ohm termination.Selectable Low Pass Filter
Each analog channel contains a software selectable low-pass filter to limit the input bandwidth. Reducing the analog input bandwidth results in a lower total noise and can be usefull especially with low voltage input signals.Multi Purpose I/O
All M4i cards offer three universal multi purpose I/O lines, which can be separately programmed as either input or output. When used as outputs, these lines can be used to output card status signals like trigger-armed or to output the trigger to synchronize external equipment.Remote Access
The digitizerNETBOX can be remotely accessed from any current Windows (starting with Windows XP) 32 bit or 64 bit system or Linux (starting with Kernel 2.6) 32 bit or 64 bit system by Ethernet. The remote access is done in the very exact programming like a locally installed product allowing to use any of the supported software packages.Product | Channels | Max. Samplerate | Max. Bandwidth |
---|---|---|---|
DN2.441-02 | 2 | 130 MS/s | 65 MHz |
DN2.441-04 | 4 | 130 MS/s | 65 MHz |
DN2.442-02 | 2 | 250 MS/s | 125 MHz |
DN2.442-04 | 4 | 250 MS/s | 125 MHz |
DN2.442-08 | 8 | 250 MS/s | 125 MHz |
DN2.445-02 | 2 | 500 MS/s | 250 MHz |
DN2.445-04 | 4 | 500 MS/s | 250 MHz |
DN2.445-08 | 8 | 500 MS/s | 250 MHz |
DN2.447-02 | 2 | 180 MS/s | 125 MHz |
DN2.447-04 | 4 | 180 MS/s | 125 MHz |
DN2.447-08 | 8 | 180 MS/s | 125 MHz |
DN2.448-02 | 2 | 400 MS/s | 250 MHz |
DN2.448-04 | 4 | 400 MS/s | 250 MHz |
DN2.448-08 | 8 | 400 MS/s | 250 MHz |
On different platforms | Bus | Max. Bus Transfer speed |
---|---|---|
DN2.441-04 | Ethernet | 70 MByte/s |
DN6.441-12 | Ethernet | 70 MByte/s |
DN6.441-16 | Ethernet | 70 MByte/s |
DN6.441-20 | Ethernet | 70 MByte/s |
DN6.441-24 | Ethernet | 70 MByte/s |
M4i.4411-x8 | PCI Express x8 | 3000 MByte/s |
M4x.4411-x4 | PXI Express | 1700 MByte/s |
Documents
Signal Processing | Signal Processing fro Digitizers |
21.02.2022 | 1 M | |
DN2.96x Datasheet | Datasheet of the generatorNETBOX DN2.96x series |
23.09.2024 | 919 K | |
DN2.44x datasheet | Data sheet of digitizerNETBOX DN2.44x |
23.09.2024 | 1 M | |
DNx.44x Manual | Manual of DN2.44x and DN6.44x family |
23.09.2024 | 12 M | |
M4 Firmware Block Average Datasheet | M4 Series Firmware Option Datasheet: Block Average |
21.02.2022 | 348 K | |
M4 Firmware Block Statistics Datasheet | M4 Series Firmware Option Data sheet: Block Statistics (Peak Detect) |
21.02.2022 | 293 K | |
IVI Driver Manual | Short Manual for IVI Driver |
21.02.2022 | 532 K | |
SBench 6 data sheet | Data sheet of SBench 6 |
15.01.2024 | 999 K | |
M4i LabVIEW Manual | Manual for LabVIEW drivers for M4i / M4x |
08.12.2023 | 6 M | |
MATLAB Manual | Manual for MATLAB driver M2p/M4i/M4x/M5i/M2i/M3i/DN2/DN6 |
13.12.2023 | 1 M | |
LabVIEW Manual | Manual for LabVIEW drivers for M2i/DN2 |
21.02.2022 | 2 M | |
SBench 6 Manual | Manual for SBench 6 |
21.02.2022 | 7 M |
WINDOWS DRIVER + SOFTWARE
Driver Win7/8/10/11 | M2p/M4i/M4x/M5i/M2i/M3i/DN2/DN6 driver for Windows 7, 8, 10, 11 (32/64 bit) |
7.04 | 25.10.2024 | 5 M |
c_header | C/C++ driver header and library files |
7.04 | 25.10.2024 | 44 K |
Control Center (32-bit) | Spectrum Control Center (32-bit) / Windows 7, 8, 10 |
2.38 | 25.10.2024 | 24 M |
Control Center (64-bit) | Spectrum Control Center (64-bit) / Windows 7, 8, 10, 11 |
2.38 | 25.10.2024 | 36 M |
Control Center WinXP | Spectrum Control Center - last Version for Windows XP |
1.74 | 21.02.2022 | 8 M |
SBench6 (32-bit) | SBench 6 (32-bit) Installer / Windows 7, 8, 10 |
6.5.09 | 25.10.2024 | 36 M |
SBench6 (64-bit) | SBench 6 (64-bit) Installer / Windows 7, 8, 10, 11 |
6.5.09 | 25.10.2024 | 49 M |
SBench6 WinXP | SBench6 - last Version for Windows XP |
6.3.5 | 21.02.2022 | 41 M |
IVI Digitizer | IVI Driver for IVI Digitizer class (32 bit) |
25.10.2024 | 3 M | |
IVI Scope | IVI Driver for IVI Scope class (32 bit) |
25.10.2024 | 3 M | |
LabView driver | M2i/M2p/M3i/M4i/M4x/M5i/DN2/DN6 LabView driver installer |
11.11.2024 | 20 M | |
Matlab driver | M2p/M4i/M4x/M5i/M2i/M3i/DN2/DN6 Matlab driver + examples installer |
11.11.2024 | 25 M | |
Examples for Windows | Windows Examples (C/C++, .NET, Delphi, Java, Python, Julia ...) |
7.04 | 25.10.2024 | 2 M |
LINUX DRIVER + SOFTWARE
Linux Driver Library | Driver libraries (no Kernel) for Linux 32 bit and 64 bit |
7.04 | 25.10.2024 | 9 M |
Control Center | Spectrum Control Center |
2.38 | 25.10.2024 | 21 M |
SBench6 | SBench 6 Linux 32 (.rpm) |
6.5.08 | 22.04.2024 | 26 M |
SBench6 | SBench 6 Linux 64 (.rpm) |
6.5.09 | 17.09.2024 | 23 M |
SBench6 | SBench 6 Linux 32 (.deb) |
6.5.08 | 22.04.2024 | 23 M |
SBench6 | SBench 6 Linux 64 (.deb) |
6.5.09 | 25.10.2024 | 22 M |
SBench6 | SBench6 Jetson (.deb) |
6.5.09 | 19.04.2024 | 11 M |
MATLAB Driver | Drivers + examples for MATLAB for Linux (DEB + RPM) |
25.10.2024 | 156 K | |
Examples for Linux | Linux Examples (C/C++, Python, Julia ...) |
7.04 | 25.10.2024 | 569 K |
Firmware
DN2 Firmware Base V27 | DN2 Standard Firmware V27 (update from versions V7-V26 to V27) |
V27 | 21.02.2022 | 52 M |
DN2 Firmware Base V7 | DN2 Standard Firmware V7 (update from versions V1-V6 to V7) |
V7 | 21.02.2022 | 11 M |
DN2/DN6 Firmware Update | DN2/DN6 Standard Firmware (install V27 first for updates prior to V27) |
V85 | 30.10.2024 | 34 M |
Case Studies
OCT Skin Cancer Scanner | OCT application for skin cancer diagnosis |
21.02.2022 | 351 K | |
CS Automotive Data Recorder | Case Automotive Data Study Recorder and Playback Solution |
21.02.2022 | 278 K |
Product Notes
General Digitizer Introduction | General Introduction to Waveform Digitizers |
21.02.2022 | 587 K | |
High-Res High BW Digitizers | Advantages of High Resolution in High Bandwidth Digitizers |
21.02.2022 | 2 M | |
Digitizer Acquisition Modes | Using modular Digitizer Acquisition Modes |
21.02.2022 | 3 M | |
Digitizer Front-End | Proper Use of Digitizer Front-End Signal Conditioning |
21.02.2022 | 3 M | |
Trigger and Sync | Trigger, Clock and Synchronization Details at high-speed Digitizers |
21.02.2022 | 1 M | |
Digitizer Software Integration | Software Support for Modular Digitizers |
21.02.2022 | 724 K | |
LXI based Digitizers | LXI based Multi-channel Digitizer Instrument |
21.02.2022 | 739 K | |
SBench 6 Introduction | SBench 6 - Data Acquisition and Analysis of Digitizer Data |
21.02.2022 | 1 M |
Application Notes
Ultrasonic Applications | Using Digitizers in Ultrasonic Applications |
21.02.2022 | 617 K | |
RF Measurements | RF Measurements using a modular Digitizer |
21.02.2022 | 838 K | |
Signal Processing Tools | Using Signal Processing Tools to enhance Digitizer Data |
21.02.2022 | 1 M | |
Using Probes & Sensors | Using Probes and Sensors with Modular Digitizers |
21.02.2022 | 858 K | |
Digitizers as Oscilloscope | Using a Digitizer as Oscilloscope |
21.02.2022 | 845 K | |
Solving Data Transfer Bottlenecks on Digitizers | Solving Data Transfer Bottlenecks on Digitizers |
21.02.2022 | 2 M | |
Teaming AWG with Digitizer | Teaming an Arbitrary Waveform Generator with a Modular Digitizer |
21.02.2022 | 919 K | |
Common Digitizer Setup Problems | Application Note: Common Digitizer Setup Problems to avoid |
21.02.2022 | 1 M | |
Mass Spectroscopy | Application Note Mass Spectroscopy |
21.02.2022 | 879 K | |
AN Amplitude Resolution | Application Note: The Amplitude Resolution of Digitizers and how it affects Measurements |
21.02.2022 | 555 K | |
AN Radar Signal Acquisition | Application Note: Radar Signal Acquisition with Modular Digitizer |
21.02.2022 | 771 K | |
AN Dynamic Parameters and Digitizers | Application Note: Dynamic Parameters and Waveform Digitizers |
21.02.2022 | 711 K | |
Aircraft Systems Testing | Testing electronic aircraft systems using modular instruments |
21.02.2022 | 3 M |
White Papers
Boxcar Average Function | White Paper 44xx Series Boxcar Average Function |
21.02.2022 | 797 K |